5 SIMPLE TECHNIQUES FOR DP50RB

5 Simple Techniques For Dp50rb

5 Simple Techniques For Dp50rb

Blog Article

Guidance 4D probe; understand the probe via the ID code; switch the 4D push signal by way of the  electrical relay to produce the 4D probe do the job Typically. 4.2.two Principal board The principle board could possibly be divided into two elements: front-close of the primary board and back again-finish of the leading board.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Be aware: Around the check, the brightness adjustment will come ahead of distinction. Soon after readjusting the watch’s distinction and brightness, modify all preset and peripheral configurations.

Don't use any cables in addition to the cables provided With all the device by Mindray. 3. Use the cable provided with this system to attach the printer. Other cables may well cause electric shock. Webpage 15: Mechanical Safety

Click on Agree and Proceed to accept cookies and go directly to the site or click on More details to check out specific descriptions of the types of cookies and opt for regardless of whether to accept particular cookies while on the website.

Whenever you prevent the scanning and the impression capture, it is best to power from the procedure and disconnect the program within the AC electrical power offer, then pull out AC electric power cables. Page 109: Battery Connecting Board

Page one hundred forty five Thoroughly clean user interface Instruments: dry soft fabric, delicate soapy water  Method:  Use dry tender cloth to wash the area with the program. Should the technique is dirty, moisten the comfortable cloth with delicate soapy drinking water and wipe off any stains. Use dry comfortable fabric to eliminate any humidity and permit all really hard surfaces to fully air-dry. Website page 146: Cleanse The Peripherals

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

iZoom™ permits precise viewing of picture from length iWorks™ Protocol assists standardize workflow and lower Examination occasions

5.two.three Geometric positioning precision Longitudinal geometric positioning accuracy  Take a look at Action: Do changes as how in tests the utmost depth. History the distance by 20mm each phase about the longitudinal targets line using the measurement caliper; Choose the value with the greatest mistake (to 20mm), work out the accuracy using the method underneath The measurement caliper ought to be positioned within the higher fringe of the goal, Be aware:... Webpage 79 Transverse geometric positioning accuracy  Test Move: Include the scan floor on the phantom with water or pair gel, gently Make contact with the probe with the scan area Alter the depth, generating the transverse targets to get displayed from the picture. Modify the main target level to become posited beside the transverse targets (the conventional will not be very clear) Change parameters like attain, TGC, producing Every transverse targets being Evidently displayed. Website page 80 5.5.two.four Blackout Area Check Move: Cover the scan area of your phantom with water or few gel, gently Get in touch with the probe Using the scan floor Modify the depth at a lessen price, and set the focus at the closest destination to the scan area. Reduce the worth of parameters like AP, Obtain till the history sound just can be observed. Web site eighty one: Software program Enhance And Servicing

Immediately after prosperous connection, the freshly extra network printer title will be shown from the printer driver checklist. Notice: Before hook up the community printer, make sure the ultrasound program and also the printer are in the same network domain, and the network is Doing work Usually. The IP deal with as well as server identify must be legitimate, e.g. Website page forty seven DICOM Location  Enter the AE Title in the ultrasound process, port and PDU in accordance with the real problem, after which click on [OK] to exit the display.

Discover improved diagnostic data via prolonged see of the anatomical framework on all linear probes

Functionality Exam five.five.one Check Approach Resolution Detection depth Geometric Posture Precision Blackout area check Report the Test pictures 5.five.two Test Content The impression utilised here is only for reference, follow the graphic influence in the real Observe: circumstance. Specifications: Exhibit: set the distinction and brightness at the clinical application price (or the default position) Operation surroundings: dark space, simulating the scientific software natural environment. Web site seventy six In ailment which the transverse resolution testing targets are horizontally shown, file the nominal length of two targets that could be clearly identified. Repeat the Procedure over to the transverse resolution testing targets at other depths. As revealed in determine underneath. Axial resolution ... Webpage 77 When using the convex probe, preserve the transverse resolution screening targets to NOTE: be displayed close to the midline. When employing a linear probe with steer perform, never turn on the steer perform when perform the transverse resolution take a look at. Zoom from the location exactly where the targets Found if vital. The diameter of your goal issue at a certain depth is equal into the transverse resolution with the depth. Website page seventy eight five.

After replacing the CPU module, important file needs to be created once again according to the new MAC handle and composed into HDD from the equipment. Or else, the configuration perform on the item will likely be dropped. Right after eliminating the CPU module, Remove panhead screws with washers (twelve M3X6) fixed on the main device box, you usually takes off the board. Website page 118 Figure eight-29 Disassemble the Control Panel Assembly (1) Maintain the higher edge of user interface assembly, and open up the Dp50rb user interface. Determine eight-30 Disassemble the Control Panel Assembly (two) After eliminating 1 countersunk head self-tapping screw PT3X10 mounted around the user interface and just take out the plug of your keyboard and the leading unit connecting cables, you could take away the control panel assembly.

A sensible new condition, Increased mobility and convenient operation make DP-50 well matched for all medical settings.

Report this page